Turbine Meter and Support Assembly for Sears, GE ( WS19X10006 ), North Star part # 7113040 This is part # 49 in our diagram.
Turbine Meter and Support Assembly for Sears, GE ( WS19X10006 ), North Star part # 7113040 KitBesides turbine and Support, this kit Includes ( 2 ) clips, 7116713, ( 2 ) o-rings, 7170288, silicone and directions. This is works with standard 3/4" valve ( not larger 1" valves ) and is shown as part # 49 in our diagram.Sears part # 4020004 or # 7117858 refers to just the "turbine", and part # 2204101 refers to the "shaft support". The combined "Assembly" is called part # 7113040.Instructions: Place valve into By Pass position ( or shut water off ). Manually advance ( using recharge button ) the softener valve to the backwash position to depressurize the system. Pull out the 2 clips holding the softener valve inlet and outlet ports. Locate and remove the old turbine & support assembly from inside the softener valve's outlet port. Insert the new turbine & support assembly into the softener valve's outlet port. Reconnect inlet and outlet ports and replace 2 clips. Place the By Pass valve into the service ( normal operation ) position to restore water to system. Push the recharge button to return the softener valve to the service ( normal operation ) position. ( positions are marked on the Cam Gear that the Motor drives ). If the system has not properly regenerated ( recharged ) it's self lately, and the water is hard, then you may want hold the Recharge Now button to have your system regenerate the resins.