Pressure Drop or Flow Rate reductions through a Water Softener / Filter System - Things to Consider
Pressure or Flow Rate Problems # 1 REASON is the RESINS in the water softener need to be changed. . and this is discussed at the end of this article ( and several other places on our website
5600 Piston Assembly Types - Softener - Filter - Low Water
Piston Assembly 60102-00, 60102-10, 60102-20 What is the Difference? Technically ( see page 8 and 16-19 in Fleck 5600 service manual ); The color of the Teflon coating of the piston may be Gree
Can an Autotrol 255 valve be converted from softener use to filter ( carbon ) use?
Can an Autotrol 255 valve be converted from softener use to filter ( carbon )use? Sure.. Just cut off the # 1 cam lobes ( brine rinse and brine refill ) on your Camshaft, so the # 1 valve disc will N
Low Pressure Through Softener On Chlorinated Water
Resin Replacement ( When, Why, and How ) When or Why to replace your softening resins. First let me say that is has been my experience that the resins
Low Pressure Through Softener On Well Water
PROBLEM: Our water comes from a well and is not chlorinated. The water pressure is good coming in but no pressure coming out. What is the problem? POSSIBLE CAUSES: 1 ) A filter ( used in 12 inch hous
Pump Pressure Low or Cycles OFF and ON ( Well Water )
QUESTION: The well pump cycles on and off rapidly. I changed the pressure switch, same thing. Pressure tank??? Pressure tank doesn't leak any water from air stem. * Good. If no water
Sediment filter ahead of the softener - When, Why, and Which one.
QUESTION: I just ordered a Galaxy 5600M system from you today. I was wondering if I should install a sediment filter ahead of the softener? * If you are on a private well and pu
No Pressure Unless the Softener is By Passed
When do the resins in the softener tank need to be changed? 1. The average water softener will not need it's resins replaced in it's life time ( 20 + years ). 2. Water softening resins need
Links to Other Websites
Water Related Sites Hard Water and Softening Explained - Treatment Systems for Household Water Supplies Clack Corporation - Drinking H2OSystems, Brine Tanks, Pres
Tank Diameter - How To Measure and Why It Matters
Do you just measure the outer resin tank diameter? * Yes, you measure the fiberglass tank that contains the resins ( or other media ). Do not be "fooled" by plastic decorative "jackets" sometimes pla
# 1 Shipping and Placing Order Questions: How to, When, How Long, From Where, What Methods
You must place order ONLINE ( or by Phone if you don't have access to a computer ) and we must receive Payment before order will be processed or shipped. You can Create an Order ( or Quote ) in online
# 3 RETURN Policy and Procedure
Return Policy and Procedure - No RMA required. SEND RETURNS TO: RETURNS / "your order number" Softenerparts.com 752 Commerce DR Unit 12 Venice, FL, 34292-1744 90 day money back - Or exchange. Only
CANADA - Does Softenerparts.com ship to Canada
Yes. We ship to Canada all the time. Small parts under 32 ounces can be shipped by Air Mail in large bubbled envelope ( and pass through Canadian Customs with little or no delay ). Larger items that
How and Why to use Acid Neutralizing Media Calcite and Corosex ( Magnesium Oxide )
If the water's pH is less then neutral ( 7.0 ), then correction is required to prevent the water from corroding the metal in your plumbing. Most common "symptoms" are blue stains from dissolved coppe
No Salt Systems for Water Softening
I see ads for "No Salt" needed water conditioners. How do they work without using salt? 1. Many dealers will advertise a no salt water conditioner. Any brand of water conditioner can be oper
Microline Filters S7125 and S7128 are Different Size - Proprietary
Customer Writes: I have an aquapro TFC-4 RO system installed in my home. I need replacement filters ( S7125 and S7128 ) and am having a hard time locating them. I see filters labeled as for TFC-4
Low water flow RO filters - Tank Pressure Problem
The number one reason for low water flow from a reverse osmosis system is low air pressure in the holding tank. The Problem: Low Volume and Poor Pressure Little to No air pressure will result in
740 and 760 Logix Timer Programming Instructions
Best place to start is the un-programmed state: Press and hold "set" ( square ) and "down" ( arrow ) buttons together for 5 seconds. Then press and hold "set" ( square ) button for 5 seconds. You will
Clogged Injector in Iron Filter
Customer writes: Thanks for your help. The problem is described in detail below, but the short version is that I couldn't get the Potassium Permanganate to draw during the regeneration cycle, even af
I have a Water Softener, but I still have odor in my water. Why is that?
1. Water softeners do not remove most taste and odor problems ( they can remove the metallic taste of iron in water ). 2. Odors from hydrogen sulfide ( "rotten egg smell" ) in wells or "bleach" sm