Please place Orders Online

Email Questions
support@softenerparts.com

Technical Support 7 days a week.




Softenerparts.com is a BBB Accredited Water Conditioning Equipment Store in Venice, FL
Knowledge Base:  

You are here: Knowledge Base : UPS
Page of 8
Account Set Up to place Order - How do I?
Question: I would like to set up an account so I can place an order. How do I? Answer: No need to sent up an account in advance. Your "account" with us is created the first time you place an online o
# 2 Pick Up at your Location ( store )?
We do not have a retail outlet. It is recommended that you place your online order and let us mail it to you. You can pick it up, but the order must still be placed ONLINE and PAID in advance of pick
440 Upgrade to 760 metered demand Logix Timer - How?
There is now a Conversion "kit" for the metered Logix Valves. Metered Control Upgrade for the Autotrol 255 / 460i is this 760 Logix Kit ( AP1255006 ) with Indoor ( open face ) Cover as shown, unle
Flow Plug in Nozzle Venturi housing - Number up or down? In Sears, GE Smart Water, North Star Systems
Flow Plug in Nozzle Venturi housing - Number up or down? I have a question about the 0.3 BLFC Button used on Sears, North Star, and G.E. / Whirlpool softeners. Part # 1148800 or GE part # WS22X100
Autotrol 155 with 440 Upgrade to 740 Day timer or 760 metered demand Logix Timer - How?
The Logix Upgrade Kits ( 740 or 760 ) are not meant to be used on the older Autotrol 155 ( 1550-TC ) Valve Bodies, but can be if you are willing to do some cutting of the new Logix Top Plate that mus
How To Repair A Logix Controller - Replacing Back Up Capacitor on the Board
How To Repair A Logix Controller that Forgets the Time Of Day After Power Interruptions The Logix Controller is designed to retain the correct time of day for up to eight hour
Which is better or cheaper... Powdered Resin Cleaners or Res-Up Liquid?
Do you sell the acid that goes in the Res-Up Feeder? If so, what is your price per gallon? ** We currently do not "ship" the Res-Up. Most Home Depot stock in the Quart size, so check with them.
# 1 Shipping and Placing Order Questions: How to, When, How Long, From Where, What Methods
You must place order ONLINE ( or by Phone if you don't have access to a computer ) and we must receive Payment before order will be processed or shipped. You can Create an Order ( or Quote ) in online
Low water flow RO filters - Tank Pressure Problem
The number one reason for low water flow from a reverse osmosis system is low air pressure in the holding tank. The Problem: Low Volume and Poor Pressure Little to No air pressure will result in
740 and 760 Logix Timer Programming Instructions
Best place to start is the un-programmed state: Press and hold "set" ( square ) and "down" ( arrow ) buttons together for 5 seconds. Then press and hold "set" ( square ) button for 5 seconds. You will
Performa Valves Keep Breaking 440i Timers - Solution is...
* PROBLEM: We have dual tanks for well water with 268/440i controllers. One is for an iron filter, the other a brine tank. We are running into a situation where timers have been destroyed because the
# 4 EMAIL QUESTIONS - Better than a PHONE call.
For the fastest assisting with troubleshooting your water softener / filter problem, we strongly encourage you to email us. Please include your brand or valve type, and a description of the problem an
940 and 960 Timer Obsolete - Replacement Options when used on 255 Valve
QUESTION: I have a Autotrol 255/960 water softener and the 960 timer has stopped working I.e.it lights up all led's when initially powered on then goes completely dark. Is there a replacement timer a
Brine Refill problem with Fleck 5600
If your Fleck 5600 Valve is not refilling the water to your brine tank, then here is a list of things to check and information to review about Brine REFILL Failure. see: Brine Line Flow Control b
Where is my package - no tracking - delays - best methods
If your order is not received in 7 - 10 days, or no tracking progress is shown online, there are several possible reasons for this. DOMESTIC ( USA ) First Class Mail orders normally arrive in 7 days
Brine Valve Replacement in Salt tank ( with Float Shut Off )
Which Brine Valve for the Salt Tank? We have several "valves" that fit in the brine tank that can be used ( all do similar function ). see: Brass 2300 Shut Off Valve and Plastic 231
Clack Circuit Board Battery Replacement Explained
"C-Series" Product Update When a 4000 or 400 series error appears on a circuit board it is recommended that the lithium battery (CR2032) be replaced. The battery helps with writing to memory in
5600 - difference between metered, 12 day softener valve and Backwash ONLY
What is the difference between metered demand control and 12 day skipper wheel? * Metered.. Meter Demand Operation ** The Fleck 5600 version - 12 day works ( regenerates ) according to the "days" or
Options - Rebuilding or Replacing your Autotrol 255/440 Valve
The Autotrol 255 Valve Body and Timer Assembly ( 440 ) can be repaired / rebuilt / upgraded, in the following ways. Please review the LINKS below 255 Rebuilding, Kit, and 440 Timer Repair Gui
Search for Part Number On Website - How do I?
Question: How Do I SEARCH for Part on the Website? Answer: The Product Search "box" is in the upper left hand side of our website, above the list of categories. ENTER your Part Number, Or a one, or t