Autotrol 155 or 255 High Water in Brine Tank - Problem No Suction or Overflowing
Last Updated: 12/18/2018

If an Autotrol Model 155 or Newer Model 255 ( since 1995 ) is not drawing the Salt Water out of the Brine tank,

What should I check?

1. Make sure all the fittings are tight. The connections at the Valve Head ( Air Check ) and at the Brine Tank ( 2 nuts of Elbow to Brine Pick Up tube ).
Also check the tubing going to the salt tank for small cracks.
Any air leak will cause the valve to not draw the water out during the regeneration cycle.
AND
the Ball in the Air Check ( assuming your 155 or 255 still have this Chamber installed on the tank adapter )...
will DROP early ( See more on this - https://www.softenerparts.com/kb_results.asp?ID=135 )

2. Make sure the drain line is not clogged or restricted. This also can cause the valves normal suction to fail.
Note: "blowing through" is not how to confirm no "partial" obstruction, but would tell you if completely clogged.
Way to check Drain Hose for partial blockage:
You'd remove and look into connection at valve, and into hose for signs of "build up".
And the Best Way to TEST is by measuring the flow rate at the end of the drain hose / pipe, during the BACKWASH cycle.
8" tanks = 1.5 gpm
9" tanks = 2.0 gpm
10" tanks = 2.4 gpm

3. Check the injector ( https://www.softenerparts.com/Injectors_For_Autotrol_Valves_28F_p/ap28f.htm )
and
injector screen ( https://www.softenerparts.com/Injector_Screen_Cap_Large_p/ap1000226.htm )
for debris or clogging.
If plugged with Debris, or if noticeably cracked, it would indicate that you've found the source of the problem.
If they look good, then they should be good, and the problem is elsewhere.

4. On Autotrol valves, check that the two large main valves ( # 2 and # 3 ) are fully closed during the Brine Rinse ( Draw ) cycle. If they fail to close, it results in no suction. In fact it will result in the valve attempting to fill the salt tank during the time it should be removing the salt water. This could be caused by something near the metal "tab" blocking the "tab" from standing straight up ( closing the rubber valve underneath, inside ), OR you could have something inside preventing full closure. On older valves, this can be caused by chlorine damage to the rubber valve discs.

See the Rebuild guides on our Do It Yourself ( DIY ) Repairs page for more about the Valve Discs functions and how to replace them.

155 Rebuild
------------------------ or ----------------------- 255 Rebuild

* How to tell if you have 155 or 255 Valve Model.

5. If your Resin Tank is INSIDE the Brine Tank ( one piece "cabinet" design popular in Europe and the U.S.A. ), you may have a leak in the RESIN TANK. Try unplugging the electric, so the Valve can NOT regenerate, and see if the water level continues to Rise from one day to the next.

6. Also check for leaking of the Brine Valve, which should be closed after the Brine Refill is completed.
You can disconnect the Brine tubing at the Control Valve end to make sure the Valve is not sending any water to the Brine Tank area ( this could occur if the # 1 Valve Disc is not closed on Autotrol Valves ).

***** In Summary
-- besides obvious loose connections or clogs, the problem is either Valve Operation or Brine Pick Up tube failure.

The Easiest way to TEST if the Valve is Creating SUCTION or not is to:

1 ) Disconnect the Brine Tubing at the Valve Head ( at your Air Check ),
2 ) Put into Brine Rinse by turning knob / pointer of 440 or 460 timer ( or advance to C2, C3 for Logix controller ).
3 ) Observe if the Ball in the Aircheck DROPS or not.
* If it DROPS, you know the Valve is working, and the problem is IN the BRINE TANK ( replacing Brine Pick Up Tube assembly is usually the answer )

****** If the ball does NOT drop, then you need to check things on the Valve end more closely.
1 ) Remove INJECTOR and check for any Debris clogging the small holes of the injector
**
2 ) If NOT clogged injector,
then
Make sure Drain is not "RESTRICTED",
By Measuring the Flow rate during the high flow of Backwash.
Use a Bucket or other container of known volume to TIME how much water comes out in ONE MINUTE.
8" tanks = 1.5 gpm
9" tanks = 2.0 gpm
10" tanks = 2.4 gpm

If LESS then you need to replace the Drain Hose and Try again.



Please Rate the Usefulness of this Article

Comments:
 

Related Articles
 > # 1 FAQ = High Water in Brine Tank - Problem -Softener does not remove the water from my salt tank or overflow
 > Distributor Failure in Bottom of Resin Tank
 > Low Pressure Through Softener On Chlorinated Water
 > Low Pressure Through Softener On Well Water
 > No Pressure Unless the Softener is By Passed
 > Average Salt Amount Needed and Normal Water Level In Brine Tank
 > Trouble Shooting Guide for the Fleck 5600 and 5600 Econominder Valve
 > STUCK Valve Fleck 5600 Rebuild Guide
 > 440iHV, 460TC, 460i Timer Assembly WARRANTY Policy of Softenerparts.com
 > Autotrol 155 or 255 - How to Tell Which You Have
 > 440 Timer Rebuilding / Repair / fix Guide
 > Backwash Plug Number - Autotrol How can I tell what number of backwash plug I need?
 > Brine Refill Problem - No water in salt tank - Autotrol
 > 740 and 760 Logix Timer Programming Instructions
 > Autotrol Valve Flow Rate Problem - Either Resin in Tank or Valve Discs not Opening Enough
 > Autotrol Valve Leaking to Drain after Replacing Valve Discs
 > Clogged Injector in Iron Filter
 > Brine Refill after Autotrol 155 or 255 Repair - Purge Air from the Valve head, Brine line & Air Check
 > Freeze Damage to Air Check Body Autotrol 255
 > How Long Until Water Feels Soft Again After Repair
 > By Pass - Autotrol Old Style - How to Use
 > Orange Sand Coming Into House
 > Performa Valves Keep Breaking 440i Timers - Solution is...
 > Refilling when it should Sucking Water out of Salt Tank ( Brine Rinse cycle ) Fleck Valve
 > 440i motor replacement guide
 > 460i Timer RESET if it is Regenerating EVERY NIGHT
 > Salt is Not Going Down. What could cause this problem?
 > Sears and GE Smartwater - Water Not Soft - Distributor Oring problem and solution
 > Setting Time of Day with the Autotrol 440 Tripper Arm Gear 99F
 > High Water in Brine Tank - Problems and Solutions
 > Brine Failure on ONE Tank Only - 9000 / 9100 Twin Alternating Valve
 > Water Soft WSCB-32D water softener = Autotrol Valve Links
 > Technetic - Series 1010 Bypass Valve
 > 440 or 440i - Which Timer Assembly Do I Have - How to Tell
 > Air Check Autotrol Old 36F or Newer Style - How to Tell - How to Clean
 > 440i Sticking in Backwash or Brine Refill
 > Tools Kit 60135-2510 for Service 1500, 2500, 2510 Seals & Spacers
 > Iron Filter, Greensand, MGS, Birm and Issues including Clogged Injector
 > Err 3 on 740,742,760, or 762 Logix Timer
 > Hard water when Autotrol Valve is working and using Salt properly - By Passing the RESIN?
 > 5600 - Manual Regenerate - Cycle Times
 > 440 or 440i or 460TC - Cycles controlled by the Camshaft used
 > Pump Pressure Low or Cycles OFF and ON ( Well Water )
 > 940 and 960 Timer Obsolete - Replacement Options when used on 255 Valve
 > Technetic 1000, Plus, 1100i replacement Valve Recommendation
 > Brine Suction problem with Fleck 5600 or similar Hankscraft Valve
 > Brine Refill problem with Fleck 5600
 > Relieving Pressure Fleck 5600 Valve
 > Air Check - Ball seated or dropping early during the BRINE/SLOW RINSE portion on the 155 or 255 Series Valve
 > 460TC or Logix 740 - Which Timer Replacement is Best?
 > 440 Upgrade to 760 metered demand Logix Timer - How?
 > Why Gravel is Not Needed in Residential Size Water Softener
 > Autotrol Date Codes - Serial Numbers
 > 5600 - difference between metered, 12 day softener valve and Backwash ONLY
 > Options - Rebuilding or Replacing your Autotrol 255/440 Valve
 > Calender Over Ride setting for 760 and 762 Logix Timer Programming
 > Backwash Plug and Injector Cap Removal Tool
 > 440 Tripper Arm Gear Repeatedly Breaking After Replacement.
 > 460TC Timer Off Set When Multiple Valves Used
 > NovRam, 460i and 460TC timers - What is the difference?
 > Top Distributor Modifications - MD1203 used with Performa 263 and 268
 > Fittings Measurements Different Then Expected ( 1/4 and 3/8 fittings )
 > Autotrol 155 with 440 Upgrade to 740 Day timer or 760 metered demand Logix Timer - How?
 > Fleck Valve - Greensand application - Purple Water After Regeneration
 > Brine Suction problem or High Water in Salt tank with Clack WS1 Valve
 > Fleck 3200 timer problems - if "stalling" or not "advancing".
 > Pressure Drop or Flow Rate reductions through a Water Softener / Filter System - Things to Consider
 > Gears, Housing, Motor Inside the 460i and 460TC timers - What is the difference?
 > Fleck 5600 - Power Head replacement - Standard in place of "L" Bracket
 > Autotrol 155 ( 1550-TC ) Valve Leaks - How to solve them
 > How To Repair A Logix Controller - Replacing Back Up Capacitor on the Board
 > Model 172 and 180 are Obsolete - Commercial Autotrol Valves and Parts
 > HANKSCRAFT H2O PRODUCTS and Replacement Valves
 > By Pass - Autotrol Old Style - Leaking When Connected to New Autotrol Valve
 > Screen shows 1.1 on 740,742,760, or 762 Logix Timer - Button Test Mode
 > Fleck 2500 leak to drain - Reasons why valve is still leaking after replacing the Seals & Spacers ( 60021 )
 > Can an Autotrol 255 valve be converted from softener use to filter ( carbon ) use?
 > Alternate Drain Fitting that comes with every Hankscraft Valve
 > Model 360, 363 and 368 Autotrol Valves and Parts
 > Turbulator - Why Would Someone Use This Over A Standard Bottom Distributor Basket / Riser Pipe?
 > 3 ways the Backwash cycle could be "blocked" in an Autotrol system
 > MediaGuard filter on Distributor Tube can cause pressure loss
 > Cabinet Model Design - Pros and Cons
 > Autotrol 163 or 168 replacement Valve Recommendation is Performa 263 or 268
 > Backwash Only Valve Replacement Options
 > Autotrol 163 or 168 Rebuild Kits
 > 440 - 460 Output Gear Repeatedly Breaking After Replacement.
 > Autotrol 155 or 255 - Injector Size / Color - Why BLUE is sometimes used on 8 inch tanks
 > Motor Identification - How to determine Type and Part Number