BLFC button question 0.25 versus 0.50 gpm with Fleck
Last Updated: 09/26/2019
Customer Writes:

I noticed that the new Injector drain assembly that I got from you guys has a smaller number that the one I have - the one that connects to the brine tank is wrong- the new one is 0.25 GPM and 0.75 LB salt/min my old one is 0.5 GPM and 1.5LB salt/min. What would be the difference with the 2 assembly. And is it going to affect the operation of the device? What can we do to fix this issue?

** There are 3 different BLFC ( brine line flow control ) BUTTONS used ( 0.25 gpm, 0.50 gpm. and 1.0 gpm ).
Each "matches" the Label on the Brine Cam Gear.
We ( and most companies ) use the 0.25 gpm BLFC ( and matching Brine Cam Gear, 3 - 18 lbs., PN 60514 ), and if you have ( had ) the 0.50 gpm BLFC, it REFILLS the brine tank TWICE as fast as the 0.25 gpm.
So, the new 0.25 gpm BLFC is refilling slower ( 1/2 as fast ) and this would mean you need to "Double" the setting on your Brine Cam Gear ( yours is mark 6 - 36 lbs., PN 60514-01 ) to get the same amount of water added to the salt tank during Brine Refill. For Example: If Brine Cam Gear setting is lined up with 6 lbs. now, you'd move to 12 lbs. to get the same amount of water as before.
OR
you can change the BLFC button ( pull out the new 0.25 gpm BLFC and re-use your old 0.50 gpm BLFC in place of it ).
NOTE: BLFC buttons can be Black or Blue in color.

see:
OR
you can replace the Brine Cam Gear with the "matching" gear ( note.. it's only the Label that is different between Brine cam gears.. not the gear it's self ).
see:
and yours now should be this one,
and this button,

***** My recommendation is to switch out the Buttons ( re-use 0.50 gpm ),
or re-set the Brine Cam Gear salt setting ( double ).

For an instructional Video about manually advancing the front control knob through the Cycles of Regeneration,
See the video listed below this product ( 12 day power head ) for a better understanding of operation,
Fleck 5600 12 Day Cycles and Setting




Please Rate the Usefulness of this Article

Comments:
 

Related Articles
 > # 1 FAQ = High Water in Brine Tank - Problem -Softener does not remove the water from my salt tank or overflow
 > Trouble Shooting Guide for the Fleck 5600 and 5600 Econominder Valve
 > STUCK Valve Fleck 5600 Rebuild Guide
 > Fleck 5600 parts rebuild with or without replacing the Timer Motor
 > Fleck 5600 Still Getting Stuck After Replacing the Pistons and Seals Kit
 > How to Set Meter without the People or Hardness Labels on Fleck Econominder Valves
 > New Timer Motor 18743 kicks the unit into 'REGEN', but that's as far as it will go.
 > Refilling when it should Sucking Water out of Salt Tank ( Brine Rinse cycle ) Fleck Valve
 > Program Wheel replacement on Fleck 5600 Valve
 > Brine Failure on ONE Tank Only - 9000 / 9100 Twin Alternating Valve
 > Water Flowing to Salt Tank after replacing Brine Valve Piston Assembly Fleck part 60032
 > Fleck Valve Leaking to Drain Continuously
 > Switches Breaking Fleck 9000, 9100, or 9500 Valves
 > Tools Kit 60135-2510 for Service 1500, 2500, 2510 Seals & Spacers
 > Continually Cycling ( Regenerating ) Problem - Fleck 9000, 9100, or 9500 Valve
 > 5600 Piston Assembly Types - Softener - Filter - Low Water
 > 5600 - Manual Regenerate - Cycle Times
 > Brine Suction problem with Fleck 5600 or similar Hankscraft Valve
 > Brine Refill problem with Fleck 5600
 > Relieving Pressure Fleck 5600 Valve
 > Fleck 3600 Valve Obsolete but can be Replaced
 > Brine Cam Gear Sheared and Broken Off Plastic Housing Inside
 > Meter - Checking the Operation of the Fleck 3/4" Meter Cover
 > Meter - Cover Replaced, but Still not working..
 > 5600 - difference between metered, 12 day softener valve and Backwash ONLY
 > Photos 5600SE, 5600SXT, 6600, and 6700 - Which Kit or Pistons for these Electronic Timers
 > Fleck 5600 SE or SXT are NOT the same as Mechanical Versions of Fleck 5600
 > Fleck 5600 SE or SXT are NOT Recommended over Mechanical Fleck 5600
 > Fleck SE or SXT Error Codes
 > Meter - Leak at Cable Connection Hole on the Fleck 3/4" Meter Cover
 > Fleck 24 volt AC transformer - Which to Choose
 > Fleck Valve - Greensand application - Purple Water After Regeneration
 > Fleck 3200 timer problems - if "stalling" or not "advancing".
 > Fleck Yoke Dimensions - Internal, External and Center To Center
 > Fleck 5600 - Power Head replacement - Standard in place of "L" Bracket
 > Fleck Piston 24507 - Fleck Model 5656 / 5665 UF are NOT the same as Mechanical Versions of Fleck 5600
 > Valve Replacements - Fleck 8500 / Twinflo 100E with Fleck 9100 or a single valve / tank option
 > Fleck 2500 leak to drain - Reasons why valve is still leaking after replacing the Seals & Spacers ( 60021 )
 > Turbulator - Why Would Someone Use This Over A Standard Bottom Distributor Basket / Riser Pipe?
 > Meter Cable Length and Part Numbers for Mechanical Fleck Meter Covers / Models
 > Backwash Only Valve Replacement Options
 > Fleck 5600 Econominder - Replacement - Repair Options
 > Meter - Cover Replacement - How Long Should This Part Last?
 > Fleck 5600 Replacement Timer Motor - Life Expectancy
 > Motor Identification - How to determine Type and Part Number