Why Gravel is Not Needed in Residential Size Water Softener
Last Updated: 01/10/2013
I read your article about how to replace resin.
I am in the process of doing it myself but curious why you do not recommend
that tanks under 12" require gravel.
I want to do this right but I am sure that my existing setup has gravel in place.

Thank you for your time with my question.

Jeff

****

Less than 5% of residential softeners have gravel in them, and the only reason is to be "different", or in a few cases because the dealer added a cup or two of activated carbon ( waste of time, as too little carbon in the tank to do much for very long ) when "building" the system.

The main problem I have with the use of Gravel ( that is Not needed ) in residential size tanks is the fact that once you have added the Media to the Tank, should you ever remove the Valve from the Tank, and the Pipe slides up an inch or two ( which is common ) you will NOT be able to put the Valve back on the tank, until you have dumped everything out, put the pipe back on the bottom of the tank, and added the "media" back in.

Having run into this problem a time of two, and the fact that 95% of the units do not have gravel in them is why I recommend that you do not add gravel when replacing the Resin in your water softener.

If you want to add it, it should not "hurt" anything, but since your flow rates in a house peak around 8 gpm, it's a waste of time, money, and "space" in the tank ( the empty space is for "expansion during the back wash cycle ) to add gravel to the residential size unit.

Resin is fairly uniform in size, and the slots of the bottom distributor are sized to prevent the normal resin bead from getting through these slots.
The resins will only get through if the resin beads have begun to "break down" due to years of exposure to highly chlorinated city water ( at which time pressure will drop as the slots begin to get "clogged" and you would "know" it's time to replace the Resin in the tank, in order to restore normal flow rate through the tank ).

You can replace the distributor tube ( although not normally "Necessary" ) by purchasing a new "bottom" distributor and gluing it to a piece of PVC pipe. SEE: DISTRIBUTOR - BOTTOM 1.05 O.D. This part combines with a piece of 3/4" PVC pipe( 1.05" O.D. ).
And when you check the resin level in the tank, it needs to be at least 1/2 full ( typically 50 - 65% full ). SEE: RESIN REPLACEMENT GUIDE

Please Rate the Usefulness of this Article

Comments:
 

Related Articles
 > # 1 FAQ = High Water in Brine Tank - Problem -Softener does not remove the water from my salt tank or overflow
 > Links to Other Websites
 > Distributor Failure in Bottom of Resin Tank
 > How To Replace Media ( Carbon, Birm, Greensand, or Calcite ) in Filter Tank
 > How and Why to use Acid Neutralizing Media Calcite and Corosex ( Magnesium Oxide )
 > Low Pressure Through Softener On Chlorinated Water
 > Low Pressure Through Softener On Well Water
 > No Pressure Unless the Softener is By Passed
 > How a water softener actually works and why does it feel slimy
 > Average Salt Amount Needed and Normal Water Level In Brine Tank
 > Salt Usage In Water Softening
 > No Salt Systems for Water Softening
 > Dishwasher Glassware Etching Cause Explained
 > Air in water lines after Softener Regenerates
 > Trouble Shooting Guide for the Fleck 5600 and 5600 Econominder Valve
 > STUCK Valve Fleck 5600 Rebuild Guide
 > Clogged Injector in Iron Filter
 > Common Water Problems
 > ECO - Friendly Alternative to SALT Softeners
 > How do you determine if you actually need a softener?
 > How do you put a softener out of service without damaging it?
 > How Long Until Water Feels Soft Again After Repair
 > Hydrogen Sulfide levels affected by amount of water used and the ground water table
 > Will a Water Softener remove the iron from my water?
 > Iron Staining and my Water Softener seems to be working okay, Why is that?
 > Odor - Sulfur (Hydrogen Sulfide) in your water
 > I have a Water Softener, but I still have odor in my water. Why is that?
 > Orange Sand Coming Into House
 > Refilling when it should Sucking Water out of Salt Tank ( Brine Rinse cycle ) Fleck Valve
 > Salt is Not Going Down. What could cause this problem?
 > Salty Water Taste in the Morning
 > Sears and GE Smartwater - Water Not Soft - Distributor Oring problem and solution
 > High Water in Brine Tank - Problems and Solutions
 > Sodium in the Water Softening
 > What Brine ( Salt ) Setting Amount to Use?
 > Will a Water Softener make my water safe to drink?
 > Carbon replacement - How often should you replace the carbon in a whole house unit?
 > Stains in Laundry - several possible causes
 > Tools Kit 60135-2510 for Service 1500, 2500, 2510 Seals & Spacers
 > Iron Filter, Greensand, MGS, Birm and Issues including Clogged Injector
 > Looking for someone to Service My Water Softner ( Softener ) in my area.
 > Adding Carbon to Resin in same Tank - Not Recommended
 > 5600 - Manual Regenerate - Cycle Times
 > Pump Pressure Low or Cycles OFF and ON ( Well Water )
 > Brine Suction problem with Fleck 5600 or similar Hankscraft Valve
 > Brine Refill problem with Fleck 5600
 > Relieving Pressure Fleck 5600 Valve
 > Stinky - Rotten Egg - Odor
 > Sodium Levels in Water when Softened
 > Air Check inside Brine Tank can becomes Stuck or Water Logged
 > Aerator Use and Cleaning Q & A
 > Air Check - Ball seated or dropping early during the BRINE/SLOW RINSE portion on the 155 or 255 Series Valve
 > Brine Valve Replacement in Salt tank ( with Float Shut Off )
 > UV for Water Purification - Does it Work?
 > 5600 - difference between metered, 12 day softener valve and Backwash ONLY
 > Pyrolox - How To Replace / Use in Filter Tank
 > Frequency of Regeneration - How Often Should Softener Recharge?
 > Black water into the house in the morning after it has cycled ( regenerated )
 > Fittings Measurements Different Then Expected ( 1/4 and 3/8 fittings )
 > Choosing a Resin - What is the Difference
 > Whole House Carbon Filter - Which is best for city water?
 > Basic Installation Guide for New Water Softener
 > Which is better or cheaper... Powdered Resin Cleaners or Res-Up Liquid?
 > Fleck Valve - Greensand application - Purple Water After Regeneration
 > Choosing a Softener System - Which Brand is Best?
 > Sediment filter ahead of the softener - When, Why, and Which one.
 > Brine Tank Assembly - Questions, Answers, Video Link
 > Brine Suction problem or High Water in Salt tank with Clack WS1 Valve
 > ChemTech and Pulsafeeder chlorine solution pumps
 > Fleck 3200 timer problems - if "stalling" or not "advancing".
 > Potassium Chloride - Substitute for Salt ( Sodium Chloride )
 > Pressure Drop or Flow Rate reductions through a Water Softener / Filter System - Things to Consider
 > BIRM - How To Replace / Use in Filter Tank
 > Fleck 5600 - Power Head replacement - Standard in place of "L" Bracket
 > HANKSCRAFT H2O PRODUCTS and Replacement Valves
 > Fleck 2500 leak to drain - Reasons why valve is still leaking after replacing the Seals & Spacers ( 60021 )
 > Recommendation of Fleck 5600 Econominder and Hankscraft Equivalent water softener replacement valves - Which Brand is Best?
 > Alternate Drain Fitting that comes with every Hankscraft Valve
 > How does Hankscraft metered valve compare with the Fleck 5600 or the Hankscraft digital unit in terms of lasting durability
 > MediaGuard filter on Distributor Tube can cause pressure loss
 > Cabinet Model Design - Pros and Cons
 > AIR INJECTION OXIDIZING FILTER SYSTEM = AIO
 > Backwash Only Valve Replacement Options
 > Do I need an Iron Filter?
 > Salty Water Taste - New Valve Installation
 > Autotrol 155 or 255 High Water in Brine Tank - Problem No Suction or Overflowing
 > Motor Identification - How to determine Type and Part Number
 > Irrigation - Iron Removal options