# 1 FAQ = High Water in Brine Tank - Problem -Softener does not remove the water from my salt tank or overflow
Last Updated: 12/18/2018
My softener does not remove the water from my salt tank when it regenerates.
What should I check?

1. Make sure all the fittings are tight. Also check the tubing going to the salt tank for small cracks. Any air leak will cause the valve to not draw the water out during the regeneration cycle.

2. Make sure the drain line is not clogged or restricted. This also can cause the valves normal suction to fail.
Note: "blowing through" is not how to confirm no "partial" obstruction, but would tell you if completely clogged.
Way to check Drain Hose for partial blockage:
You'd remove and look into connection at valve, and into hose for signs of "build up".
And the Best Way to TEST is by measuring the flow rate at the end of the drain hose / pipe, during the BACKWASH cycle.
8" tanks = 1.5 gpm
9" tanks = 2.0 gpm
10" tanks = 2.4 gpm

3. Check the injector and injector screen for debris or clogging.
If plugged with Debris, or if noticeably cracked, it would indicate that you've found the source of the problem.
Rubber o-rings or Gasket ( if any used for your model ) should also "look" good when you inspect.
If they look good, then they should be good, and the problem is elsewhere.

4. On Autotrol valves, check that the two large main valves ( # 2 and # 3 ) are fully closed during the Brine Rinse ( Draw ) cycle. If they fail to close, it results in no suction. In fact it will result in the valve attempting to fill the salt tank during the time it should be removing the salt water. This could be caused by something near the metal "tab" blocking the "tab" from standing straight up ( closing the rubber valve underneath, inside ), OR you could have something inside preventing full closure. On older valves, this can be caused by chlorine damage to the rubber valve discs.
See the Rebuild guides on our Do It Yourself ( DIY ) Repairs page for more about the Valve Discs functions and how to replace them.
155, 168 or 255 or 268 Performa

For Piston Assembly or Rotor Disc Valves, the problem can be caused by internal leaks due to wear or damaged Pistons, Rotor, and especially the Seals they contact with in the control valve. Replacement guides for common types will be found on our DIY repairs page.
SEARS, GE SmartWater, NorthStar - specific things to check are Gasket in Venturi assembly, and the Seal Kit rubber.


MORE > Brine Suction problem Help if you have the Fleck 5600 valve.

MORE > Brine Suction problem or High Water in Salt tank with Clack WS1 Valve

5. If your Resin Tank is INSIDE the Brine Tank ( one piece "cabinet" design popular in Europe and the U.S.A. ), you may have a leak in the RESIN TANK. Try unplugging the electric, so the Valve can NOT regenerate, and see if the water level continues to Rise from one day to the next.

6. Also check for leaking of the Brine Valve, which should be closed after the Brine Refill is completed.
You can disconnect the Brine tubing at the Control Valve end to make sure the Valve is not sending any water to the Brine Tank area ( this could occur if the # 1 Valve Disc ( on Autotrol Valves ) or Brine Piston Assembly ( on Fleck Valves ) or Internal Seal leak ( on Rotor Disc type valves ) is being held open by debris of some kind or is very worn due to age.

Be sure to check out the Knowledge Base of Questions and Answers page,

And WatermanAndy's YouTube Channel Videos




Please Rate the Usefulness of this Article

Comments:
 

Related Articles
 > Links to Other Websites
 > Distributor Failure in Bottom of Resin Tank
 > How and Why to use Acid Neutralizing Media Calcite and Corosex ( Magnesium Oxide )
 > Low Pressure Through Softener On Chlorinated Water
 > Low Pressure Through Softener On Well Water
 > No Pressure Unless the Softener is By Passed
 > How a water softener actually works and why does it feel slimy
 > Average Salt Amount Needed and Normal Water Level In Brine Tank
 > Salt Usage In Water Softening
 > No Salt Systems for Water Softening
 > Dishwasher Glassware Etching Cause Explained
 > Air in water lines after Softener Regenerates
 > Trouble Shooting Guide for the Fleck 5600 and 5600 Econominder Valve
 > STUCK Valve Fleck 5600 Rebuild Guide
 > 440iHV, 460TC, 460i Timer Assembly WARRANTY Policy of Softenerparts.com
 > Autotrol 155 or 255 - How to Tell Which You Have
 > 440 Timer Rebuilding / Repair / fix Guide
 > Backwash Plug Number - Autotrol How can I tell what number of backwash plug I need?
 > Brine Refill Problem - No water in salt tank - Autotrol
 > 740 and 760 Logix Timer Programming Instructions
 > Autotrol Valve Flow Rate Problem - Either Resin in Tank or Valve Discs not Opening Enough
 > Autotrol Valve Leaking to Drain after Replacing Valve Discs
 > Brine Draw Failure in Sears, GE Smart Water, North Star Systems, Whirlpool, Morton, Ecodyne, Ecopure and others
 > Clogged Injector in Iron Filter
 > Common Water Problems
 > Brine Refill after Autotrol 155 or 255 Repair - Purge Air from the Valve head, Brine line & Air Check
 > ECO - Friendly Alternative to SALT Softeners
 > Error Codes Sears, GE, NorthStar Timers
 > Fleck 5600 parts rebuild with or without replacing the Timer Motor
 > Fleck 5600 Still Getting Stuck After Replacing the Pistons and Seals Kit
 > Freeze Damage to Air Check Body Autotrol 255
 > GE SmartWater Switch Activation Not in Sync with Cam Gear
 > How do you determine if you actually need a softener?
 > How do you put a softener out of service without damaging it?
 > How Long Until Water Feels Soft Again After Repair
 > How to Set Meter without the People or Hardness Labels on Fleck Econominder Valves
 > By Pass - Autotrol Old Style - How to Use
 > Hydrogen Sulfide levels affected by amount of water used and the ground water table
 > Will a Water Softener remove the iron from my water?
 > Iron Staining and my Water Softener seems to be working okay, Why is that?
 > New Timer Motor 18743 kicks the unit into 'REGEN', but that's as far as it will go.
 > Odor - Sulfur (Hydrogen Sulfide) in your water
 > I have a Water Softener, but I still have odor in my water. Why is that?
 > Orange Sand Coming Into House
 > Performa Valves Keep Breaking 440i Timers - Solution is...
 > Refilling when it should Sucking Water out of Salt Tank ( Brine Rinse cycle ) Fleck Valve
 > 440i motor replacement guide
 > Program Wheel replacement on Fleck 5600 Valve
 > 460i Timer RESET if it is Regenerating EVERY NIGHT
 > Salt is Not Going Down. What could cause this problem?
 > Salty Water Taste in the Morning
 > Sears and GE Smartwater - Water Not Soft - Distributor Oring problem and solution
 > Sears Valve Body drips at INLET
 > Setting Time of Day with the Autotrol 440 Tripper Arm Gear 99F
 > High Water in Brine Tank - Problems and Solutions
 > Sodium in the Water Softening
 > Brine Failure on ONE Tank Only - 9000 / 9100 Twin Alternating Valve
 > Visual Guide - Installing Rotor Disc and Seal Kit Sears Type Valve
 > Water Flowing to Salt Tank after replacing Brine Valve Piston Assembly Fleck part 60032
 > Water Soft WSCB-32D water softener = Autotrol Valve Links
 > What Brine ( Salt ) Setting Amount to Use?
 > Why is new Venturi Nozzle Assembly wet and label coming off?
 > Will a Water Softener make my water safe to drink?
 > Fleck Valve Leaking to Drain Continuously
 > Switches Breaking Fleck 9000, 9100, or 9500 Valves
 > Technetic - Series 1010 Bypass Valve
 > 440 or 440i - Which Timer Assembly Do I Have - How to Tell
 > Air Check Autotrol Old 36F or Newer Style - How to Tell - How to Clean
 > Stains in Laundry - several possible causes
 > Clearing Memory in Sears, GE, and NorthStar Circuit Board
 > 440i Sticking in Backwash or Brine Refill
 > Tools Kit 60135-2510 for Service 1500, 2500, 2510 Seals & Spacers
 > Iron Filter, Greensand, MGS, Birm and Issues including Clogged Injector
 > Looking for someone to Service My Water Softner ( Softener ) in my area.
 > Err 3 on 740,742,760, or 762 Logix Timer
 > Continually Cycling ( Regenerating ) Problem - Fleck 9000, 9100, or 9500 Valve
 > 5600 Piston Assembly Types - Softener - Filter - Low Water
 > Hard water when Autotrol Valve is working and using Salt properly - By Passing the RESIN?
 > 5600 - Manual Regenerate - Cycle Times
 > 440 or 440i or 460TC - Cycles controlled by the Camshaft used
 > Pump Pressure Low or Cycles OFF and ON ( Well Water )
 > 940 and 960 Timer Obsolete - Replacement Options when used on 255 Valve
 > Technetic 1000, Plus, 1100i replacement Valve Recommendation
 > Brine Suction problem with Fleck 5600 or similar Hankscraft Valve
 > Brine Refill problem with Fleck 5600
 > Relieving Pressure Fleck 5600 Valve
 > Stinky - Rotten Egg - Odor
 > Sodium Levels in Water when Softened
 > Air Check inside Brine Tank can becomes Stuck or Water Logged
 > Aerator Use and Cleaning Q & A
 > Air Check - Ball seated or dropping early during the BRINE/SLOW RINSE portion on the 155 or 255 Series Valve
 > 460TC or Logix 740 - Which Timer Replacement is Best?
 > Brine Valve Replacement in Salt tank ( with Float Shut Off )
 > Fleck 3600 Valve Obsolete but can be Replaced
 > UV for Water Purification - Does it Work?
 > Brine Cam Gear Sheared and Broken Off Plastic Housing Inside
 > Meter - Checking the Operation of the Fleck 3/4" Meter Cover
 > Meter - Cover Replaced, but Still not working..
 > 440 Upgrade to 760 metered demand Logix Timer - How?
 > Why Gravel is Not Needed in Residential Size Water Softener
 > Autotrol Date Codes - Serial Numbers
 > Flow Plug in Nozzle Venturi housing - Number up or down? In Sears, GE Smart Water, North Star Systems
 > Which Valve Size - 3/4" or 1" Valve for Rotor Disc and Seal Kit?
 > 5600 - difference between metered, 12 day softener valve and Backwash ONLY
 > Photos 5600SE, 5600SXT, 6600, and 6700 - Which Kit or Pistons for these Electronic Timers
 > Options - Rebuilding or Replacing your Autotrol 255/440 Valve
 > Frequency of Regeneration - How Often Should Softener Recharge?
 > Calender Over Ride setting for 760 and 762 Logix Timer Programming
 > Backwash Plug and Injector Cap Removal Tool
 > 440 Tripper Arm Gear Repeatedly Breaking After Replacement.
 > 460TC Timer Off Set When Multiple Valves Used
 > NovRam, 460i and 460TC timers - What is the difference?
 > Ecowater proprietary models are 2000, 2002, 2200, 2500, 2502, 3000, 3002, 3200, 3500 Series and late model 2100 PF series, and we can't get most parts
 > Fleck 5600 SE or SXT are NOT the same as Mechanical Versions of Fleck 5600
 > Fleck 5600 SE or SXT are NOT Recommended over Mechanical Fleck 5600
 > Top Distributor Modifications - MD1203 used with Performa 263 and 268
 > Fleck SE or SXT Error Codes
 > Fittings Measurements Different Then Expected ( 1/4 and 3/8 fittings )
 > Autotrol 155 with 440 Upgrade to 740 Day timer or 760 metered demand Logix Timer - How?
 > Meter - Leak at Cable Connection Hole on the Fleck 3/4" Meter Cover
 > Choosing a Resin - What is the Difference
 > Basic Installation Guide for New Water Softener
 > Fleck 24 volt AC transformer - Which to Choose
 > Which is better or cheaper... Powdered Resin Cleaners or Res-Up Liquid?
 > Fleck Valve - Greensand application - Purple Water After Regeneration
 > Choosing a Softener System - Which Brand is Best?
 > Sediment filter ahead of the softener - When, Why, and Which one.
 > North Star Condition Softeners and Water Filters
 > Brine Tank Assembly - Questions, Answers, Video Link
 > Brine Suction problem or High Water in Salt tank with Clack WS1 Valve
 > BLFC button question 0.25 versus 0.50 gpm with Fleck
 > ChemTech and Pulsafeeder chlorine solution pumps
 > Fleck 3200 timer problems - if "stalling" or not "advancing".
 > Potassium Chloride - Substitute for Salt ( Sodium Chloride )
 > Pressure Drop or Flow Rate reductions through a Water Softener / Filter System - Things to Consider
 > Gears, Housing, Motor Inside the 460i and 460TC timers - What is the difference?
 > Fleck Yoke Dimensions - Internal, External and Center To Center
 > Fleck 5600 - Power Head replacement - Standard in place of "L" Bracket
 > Fleck Piston 24507 - Fleck Model 5656 / 5665 UF are NOT the same as Mechanical Versions of Fleck 5600
 > Autotrol 155 ( 1550-TC ) Valve Leaks - How to solve them
 > How To Repair A Logix Controller - Replacing Back Up Capacitor on the Board
 > Model 172 and 180 are Obsolete - Commercial Autotrol Valves and Parts
 > HANKSCRAFT H2O PRODUCTS and Replacement Valves
 > By Pass - Autotrol Old Style - Leaking When Connected to New Autotrol Valve
 > Screen shows 1.1 on 740,742,760, or 762 Logix Timer - Button Test Mode
 > Valve Replacements - Fleck 8500 / Twinflo 100E with Fleck 9100 or a single valve / tank option
 > Fleck 2500 leak to drain - Reasons why valve is still leaking after replacing the Seals & Spacers ( 60021 )
 > Can an Autotrol 255 valve be converted from softener use to filter ( carbon ) use?
 > Recommendation of Fleck 5600 Econominder and Hankscraft Equivalent water softener replacement valves - Which Brand is Best?
 > Alternate Drain Fitting that comes with every Hankscraft Valve
 > Model 360, 363 and 368 Autotrol Valves and Parts
 > Turbulator - Why Would Someone Use This Over A Standard Bottom Distributor Basket / Riser Pipe?
 > Sears Kenmore Regeneration Cycle Process and Flow Direction
 > 3 ways the Backwash cycle could be "blocked" in an Autotrol system
 > Meter Cable Length and Part Numbers for Mechanical Fleck Meter Covers / Models
 > How does Hankscraft metered valve compare with the Fleck 5600 or the Hankscraft digital unit in terms of lasting durability
 > MediaGuard filter on Distributor Tube can cause pressure loss
 > Cabinet Model Design - Pros and Cons
 > AIR INJECTION OXIDIZING FILTER SYSTEM = AIO
 > Autotrol 163 or 168 replacement Valve Recommendation is Performa 263 or 268
 > Backwash Only Valve Replacement Options
 > Autotrol 163 or 168 Rebuild Kits
 > Fleck 5600 Econominder - Replacement - Repair Options
 > Meter - Cover Replacement - How Long Should This Part Last?
 > Fleck 5600 Replacement Timer Motor - Life Expectancy
 > Do I need an Iron Filter?
 > PWA AC or DC version - and conversion guide
 > Salty Water Taste - New Valve Installation
 > 440 - 460 Output Gear Repeatedly Breaking After Replacement.
 > Autotrol 155 or 255 High Water in Brine Tank - Problem No Suction or Overflowing
 > Autotrol 155 or 255 - Injector Size / Color - Why BLUE is sometimes used on 8 inch tanks
 > Motor Identification - How to determine Type and Part Number
 > Irrigation - Iron Removal options
 > Compare- By Pass Valve Large Version 7214383, WS15X10026 - High Flow 1" Valve Body - Standard ( 3/4" ) valve body, By Pass Valve 7278434, WS15X10053