Fleck SE or SXT ERROR Codes
The Electronic Fleck Valves ( SE and newer SXT ) ERROR Codes
Err 1 ( continuously running motor ) is usually a broken CAM or defective Switch.
see cam
PN 17438
see switch ( note there are two of the same switch, so replace both to be sure )
Micro_Switch_for_Drive_Motor 10218
Or the 5600SXT Power Head ( with new board and the housing with the Cam and Switches ),
here:
Power_Head_5600SXT_metered_FL56SXT
SE and SXT controllersFor other parts available for the 5600 SE and Various SXT controllers see:
And finally,
NOTE: We do not recommend the Fleck SE or SXT timers, but rather the mechanical versions.
Why - SXT Not Recommended
7000 Board UD Sync ( UD 5y nc )
UD Sync is an encoder issue.The board is not installed correctly on the unit causing the encoder not to be alignedwith the slotted gear.
Slotted gear is not centered between the two sensors on the backside of the board, Issuewith slotted gear, a slot plugged with debris or a broken slot.
Capacitor wasn’t drain erasing last know position the valve currently is not in. Unplug unit and hold black reset button on the back of the board down for 10seconds. Plug back in.
UD Sync is the 2 sensor eyes cannot read the slotted gear that passes between them.
UD Sync means it is looking for service position.
If it cannot find it the timer will stay in UD sync.