Trouble-Shooting
Autotrol Model 155
| PROBLEM | POSSIBLE CAUSE | CORRECTION | |||
|
1. |
Control will not regenerate automatically |
A. |
Electric cord unplugged. |
A. |
Connect to power. |
| B. | Defective timer motor. | B. |
Replace motor. |
||
| C. | Depress pins for days regeneration required. | ||||
| C. | |||||
| Skipper pins not down on timer skipper wheel. | |||||
| D. | Replace stripped gear (s). Replace housing if gear post broken. | ||||
| Stripped gear in timer control housing. | |||||
| D. | |||||
|
2. |
Control regenerates at wrong time of day. | A. | Timer set incorrectly. ( Normal regeneration time is 2 a.m. when the clock is set to the actual time of day ) |
A. |
Set clock to the correct current time of day. ( small pointer on tripper arm gear ). |
|
3. |
Control will not draw brine |
A. |
Low water pressure ( less than 20 psi ) | A. |
Set pump to maintain 20 psi. Replace any pre-filters installed ahead of softener. |
| B. | Restricted drain line | B. | Change drain to remove restriction. | ||
| C. |
Injector clogged
|
C. | Clean injector and screen. | ||
| D. | Injector
defective ( Could be worn out or damaged if used on chlorinated water source ) |
D. | Replace injector and cap | ||
| E. | Valve disc #2 and/or #3 not closing properly. ( Could be worn out or damaged if used on chlorinated water source ) | E. | Remove foreign matter from disc and check disc for closing by pushing in on stem. Replace valve set ( # 155A152 ) if needed. | ||
| F. | Air check prematurely closing | F. | Check for air leaks on air check, brine tubing, and all connections to brine pick up tube. | ||
| 4. | Brine tank overflow | A. | Brine valve disc # 1 being held open | A. | Manually operate valve stem to flush away obstruction. |
| B. | Uncontrolled brine refill flow rate | B. | Remove variable salt controller to clean it and ball ( Items 1F and 4F ). Replace 1F if needed. | ||
|
C. |
Valve disc # 2 not closed during brine draw, causing brine refill. |
C. |
Flush out foreign matter holding disc open by manually operating valve stem. ( also see 3. E. above ) | ||
|
D. |
Air leak in brine line to air check. | D. |
Check all connections in brine line for leaks. All fittings must be air tight and look for cracks on old brine tubing. | ||
|
From experience in the field, we have found that if the unit fails to regenerate, you will have either a dead timer motor, a stripped gear ( or two ), or a broken post that holds a gear in the 440 Timer Housing. Problems related to improper, or incomplete regeneration are due to: air leaks in the brine tubing connections to brine pick up tube, clogged drain lines, valve discs that have worn out ( after 10 years ) or valve discs ( and all internal rubber components ) being damaged when used on a chlorinated water source.
SEE: Rebuilding Page for more help with Autotrol repairs. |
|||||