740 and 760 Logix Timer Programming Instructions
Last Updated: 11/26/2017
Best place to start is the un-programmed state:

Press and hold "set" ( square ) and "down" ( arrow ) buttons together for 5 seconds.

Then press and hold "set" ( square ) button for 5 seconds.

You will now see three flashing lines:

* First Step is Valve type, Your Logix Timer is installed on.

Use the arrows to choose ( select ) the letter "F" if used on Backwash Only Valve, otherwise ( if water softener ) you will be setting the Resin Capacity of your Water Softener.

Step Two: Resin capacity.

Capacities:
0.75 for 24K ( 3/4 cu.ft. ) - most 8" diameter tanks
1.0 for 32K ( 1 cu.ft. ) - most 9" diameter tanks
1.25 for 40K ( 1.25 cu.ft.) - most 10" x 44" tanks
1.50 for 48K ( 1.50 cu.ft. ) - all 10" x 54" tanks
2.0 for 64K ( 2 cu.ft.) - most 12" diameter tanks
2.5 for 80K ( 2.5 cu.ft. ) - most 13" diameter tanks
3.0 for 96K ( 3 cu.ft. ) - 14" x 65" tanks

Press the set button to accept.

A. Time of day will be displayed.

1. Press the set button to make it flash.
2. Use arrows to set correct time ( note PM is indicated, and no indication is AM ).
3. Press the set button to accept.

B. Set day of week. Repeat steps 1,2, and 3 above.

C. Set time of regeneration ( typical 2:00 a.m. is used ). Repeat steps 1,2, and 3 above.

D. Set calendar override (for demand units) or days to regenerate (for timer units). Repeat steps 1,2, and 3 above.

NOTE: On demand units will normally be set to 0.

E. Set salt dosage. Repeat steps 1, 2, and 3 above.

NOTE: You have L for low, S for standard, and H for high.

Standard is the most efficient. NOTE: Newer Logix 742, and 762 should be 9 lbs. per cu.ft. as standard. You won't see L,S, or H.

F. Set estimated capacity. * Do Not Set -


NOTE: Estimated capacity is calculated by the unit. You do not want to change this value.

G. For Logix 760, 762 ( but not 740, 742 ) Set hardness level of your water ( Number of GRAINS Hardness - Adding 3 for each 1 ppm of Iron in water ). Repeat steps 1, 2, and 3 above.
And watch this Video by manufacturer - https://youtu.be/epljZD9SaA4
The unit will now display the time.

To put in Manual Regeneration

For preset time to regenerate: Press and release manual regeneration button.

For immediate regeneration: Press and hold manual regeneration button for 5 seconds.



The GE Osmonic Autotrol Valves 255 and 268 have been available with the Logix electronic controls for several years now ( 740 and 760, or 742 and 762 ). This 1 minute video shows how to start a manual regeneration for tonight or immediate start.
***

CLICK HERE FOR - 740 AND 760 PROGRAMING STEPS as shown in the Owner's Manual

You can Download a complete 740 / 760 Logix service manual from the manufacturer:
Autotrol Logix 740/760 Manual



Watch the Programming Steps to see how simple it is.

**** NOTE:
If you have the Logix 742 / 762 controller, it will "Normally" be set up for the Valve Type it's attached to, but should you get a replacement Logix controller, or the Logix control is generating an Error 3 code after running the first cycle ( C1 ), then you may need to
"Select Valve Type" step.
There are options ( different Valve Types ) you have to select from ( Your Valve Body type is marked on the silver ID sticker on the back or side of the valve body ).

255 = 255, conditioner ( water softener ).
263 = Performa filter 263, filter backwash
268 = Performa conditioner 268, ( water softener )
Also, less common Valve Types, 268FA, 273, 278, 293, 298

It's Critical that it matches your valve body type, if you are using the Logix 742 or 762 controller.

What to do if you are getting an < Err 3 on 740,742,760, or 762 Logix Timer >



Please Rate the Usefulness of this Article

Comments:
 

Related Articles
 > # 1 FAQ = High Water in Brine Tank - Problem -Softener does not remove the water from my salt tank or overflow
 > 440iHV Timer Assembly WARRANTY Policy of Softenerparts.com
 > Autotrol 155 or 255 - How to Tell Which You Have
 > 440 Timer Rebuilding / Repair / fix Guide
 > Backwash Plug Number - Autotrol How can I tell what number of backwash plug I need?
 > Brine Refill Problem - No water in salt tank - Autotrol
 > Autotrol Valve Flow Rate Problem - Either Resin in Tank or Valve Discs not Opening Enough
 > Autotrol Valve Leaking to Drain after Replacing Valve Discs
 > Brine Refill after Autotrol 155 or 255 Repair
 > Freeze Damage to Air Check Body Autotrol 255
 > By Pass - Autotrol Old Style - How to Use
 > Performa Valves Keep Breaking 440i Timers - Solution is...
 > 440i motor replacement guide
 > 460i Timer RESET if it is Regenerating EVERY NIGHT
 > Setting Time of Day with the Autotrol 440 Tripper Arm Gear 99F
 > Water Soft WSCB-32D water softener = Autotrol Valve Links
 > Technetic - Series 1010 Bypass Valve
 > 440 or 440i - Which Timer Assembly Do I Have - How to Tell
 > Air Check Autotrol Old 36F or Newer Style - How to Tell - How to Clean
 > 440i Sticking in Backwash or Brine Refill
 > Err 3 on 740,742,760, or 762 Logix Timer
 > Hard water when Autotrol Valve is working and using Salt properly - By Passing the RESIN?
 > 440 or 440i or 460TC - Manual Cycle Times if Motor Bad or No Power
 > 940 and 960 Timer Obsolete - Replacement Options when used on 255 Valve
 > Technetic 1000, Plus, 1100i replacement Valve Recommendation
 > Air Check - Ball seated or dropping early during the BRINE/SLOW RINSE portion on the 155 or 255 Series Valve
 > 460TC or Logix 740 - Which Timer Replacement is Best?
 > 440 Upgrade to 760 metered demand Logix Timer - How?
 > Autotrol Date Codes - Serial Numbers
 > Options - Rebuilding or Replacing your Autotrol 255/440 Valve
 > Calender Over Ride setting for 760 and 762 Logix Timer Programming
 > Backwash Plug and Injector Cap Removal Tool
 > 440 Tripper Arm Gear Repeatedly Breaking After Replacement.
 > 460TC Timer Off Set When Multiple Valves Used
 > NovRam, 460i and 460TC timers - What is the difference?
 > Top Distributor Modifications - MD1203 used with Performa 263 and 268
 > Fittings Measurements Different Then Expected ( 1/4 and 3/8 fittings )
 > Autotrol 155 with 440 Upgrade to 740 Day timer or 760 metered demand Logix Timer - How?
 > Gears, Housing, Motor Inside the 460i and 460TC timers - What is the difference?
 > Autotrol 155 ( 1550-TC ) Valve Leaks - How to solve them
 > How To Repair A Logix Controller - Replacing Back Up Capacitor on the Board
 > Model 172 and 180 are Obsolete - Commercial Autotrol Valves and Parts
 > By Pass - Autotrol Old Style - Leaking When Connected to New Autotrol Valve
 > Screen shows 1.1 on 740,742,760, or 762 Logix Timer - Button Test Mode
 > Can an Autotrol 255 valve be converted from softener use to filter ( carbon ) use?
 > Model 363 and 368 Autotrol Valves and Parts
 > Turbulator - Why Would Someone Use This Over A Standard Bottom Distributor Basket / Riser Pipe?
 > 3 ways the Backwash cycle could be "blocked" in an Autotrol system
 > Autotrol 163 or 168 replacement Valve Recommendation is Performa 263 or 268